Temperature probe for measuring high temperatures and high pressure loads.
High temperature measurement sensors.
Connection technology center inc.
For applications in hazardous areas the sensor is available with intrinsically safe ex ia and non incendive ex na certifications.
Further each sensor option comes in a variety of styles suited for different application needs.
Sensor thermistor thermocouple rtd pt100 temperature range.
They can be structured with a quartz element 112 115 116 series or a uht 12 element 176 series.
Temperature range 20 c to 285 c.
Stoneridge s family of high temperature 900 c sensors use a resistance temperature detector rtd which varies directly and linearly with the temperature of its environment.
High temperature dynamic pressure sensors.
For applications that exceed those temperatures imi sensors has a variety of charge mode accelerometers with integral icp amplifier that can operate at 900 ºf 482 ºc and charge mode accelerometers without integral icp.
They however provide localized temperature readings and need a cold junction compensation to maintain the temperature.
10kn per sensor tube.
Each sensor option thermocouple rtd and thermistor is unique in its design and theory of operation.
The seven basic types of temperature measurement sensors discussed here are thermocouples resistive temperature devices rtds thermistors infrared radiators bimetallic devices.
Widest type j is 210 to 1200 c type k is 95 to 1260 c other types can range as low as 270 c or as high as 3100 c.
These sensors are capable of detecting very high temperatures as high as 1700 o have a very simplistic design which makes them quite robust to shock and vibration and can have almost immediate response to temperature changes.
Temperature measuring sensors come in a wide variety and have one thing in common.
This document goes into detail about the theory of operation types and considerations surrounding three types of temperature measurement sensors.
Connection box in aluminium.
They all measure temperature by sensing some change in a physical characteristic.
The high temperature icp accelerometers are capable of withstanding continuous temperatures of 325 ºf 162 ºc.
1 7 measuring points.
Quartz sensors operate without cooling up to 750 f 399 c on compressors and pumps.
The ecm utilizes this sensor input to determine differences in air fuel ratios and other variables that affect exhaust gas emission levels.
Approved for application in atex zone 20.
High temperature differential output pressure sensor for measuring lowest pressure fluctuations in a harsh environment up to 700 c and up to 1000 c on short term.