The smc pme 500 tr is a circuit breaker analyzer that includes all the mentioned functions which can be required for the condition assessment of medium and high voltage circuit breakers.
Hv circuit breaker testing set.
200kv 300kv dc hipot tester.
The interrupter and the mechanical drive are the main components that are subject to wear and aging.
Dc hipot test set.
Circuit breaker timing test set suitable for ehv hv and mv circuit breakers built in 200 a microhmmeter static and dynamic contact resistance measurement 6 main and 6 resistive contact inputs up to 4 trip close coils control 7 analog inputs 4 auxiliary timing contact.
Guidelines for hv circuit breaker function and test methods.
Gas type testing transformer.
Ac dc vlf hipot test set ac dc hipot test set.
Quick and easy to perform on site.
Oil type hv test transformer.
Circuit breaker testing is used to test both the performance of individual switching mechanisms and the timing of the overall tripping system.
The circuit breaker has to operate within extremely tight tolerances when a disturbance is detected in the network to protect sensitive and costly components such as transformers.
Hv circuit breaker testing video circuit breakers allow the flow of energy to be controlled by safely switching currents on and off at all voltage levels of the energy grid.
Various tests can be conducted on high voltage circuit breakers to evaluate the operational performance of their different internal components.
Vlf hipot test set.
The pme 500 tr is designed with all the foregoing considerations in mind and also includes the contact resistance measurement of.
Induced withstand voltage test set.
China hv auto circuit breaker testing kit find details about china circuit breaker analyzer circuit breaker tester from hv auto circuit breaker testing kit chongqing gold mechanical electrical equipment co ltd.
The way of how to test a circuit breaker must also consider the short time that the circuit breaker is out of service minimizing the setup work connections and test complexity.
Regardless of the breaker type whether it be air blast oil vacuum or gas its important to test their components regularly to help ensure proper operation in case of a system fault or switching operation.
Dry type hv test transformer.
How to test a circuit breaker of this type depends on its maximum rated current the trip protection settings and the inverse curve types which will define the overload and short circuit trip pickup levels and time delays.
Insulating boots gloves test set.
Circuits can be tested on or off load.
Circuit breaker is one of the most important component in every electric power system.
All these features must be checked with the appropriate primary injection test set with the capacity to simulate the corresponding high current faults required and capture the answer of the breaker.
Circuit breaker testing is essential to ensure the safe and reliable performance of this key link in the power asset chain.
60kv 120kv dc hipot tester.